All
LP7151 — Double Ended Beam Load Cell, 10-125 klb
LP7151 — Double Ended Beam Load Cell, 10-125 klb

LP7151 — Double Ended Beam Load Cell, 10-125 klb

NTEP Class IIIL double ended beam load cell from 10 klb to 125 klb, 3.0 mV/V output, NPT conduit entry and IP67/IP68 sealing for truck scales.

Request a Quote Download Datasheet

Send Inquiry


  1. 400 characters left for input
Certifications Ex CPA

Overview

The LP7151 is a double ended beam load cell for truck scales, weigh bridges and weighing modules, covering 10, 20, 25, 40, 50, 60, 75, 100 and 125 klb. It carries NTEP Class IIIL approval with 10,000 multiple intervals under certificate 26-093, so it is accepted for high resolution truck weighing in the US market. Rated output is 3.0 ± 0.003 mV/V with zero balance of ±1% F.S., combined error of ±0.02% F.S. and non-repeatability of ±0.01% F.S. Creep error is ±0.025% F.S. over 30 minutes, temperature effect on zero is ±0.036% F.S. per 18 F and on output ±0.027% F.S. per 18 F. The bridge is 700 ±10 ohm input and 702 ±2 ohm output, safe overload is 150% F.S. and destructive load 300% F.S., so a truck rolling onto a deck does not damage the cell. Excitation is 10-15 V AC/DC recommended with 20 V AC/DC maximum. Construction is alloy steel or stainless steel sealed to IP67 or IP68. The beam is 7.75 in long at 10 to 25 klb, 10.25 in at 40 to 75 klb and 15.25 in at 100 to 125 klb, with end eyes that take mounting pins. Cable entry uses 1/4-18NPT on the light sizes and 1/2-14NPT on the rest, so standard US conduit fittings screw straight in. A four core cable is supplied at 39 ft or 52 ft, 0.23 in in diameter.

Specifications

Specification

Value

Rated capacity

10/20/25/40/50/60/75 klb; 100-125 klb

Accuracy class

C3

Rated output

3.0 ±0.003 mV/V

Temp effect on zero

±0.02% F.S./10 F

Temp effect on sensitivity

±0.02% F.S./10 F

Creep (30 min)

±0.02% F.S.

Input resistance

700 ±10 ohm

Output resistance

702 ±2 ohm

Operating temp range

-22-158 F

Insulation resistance

≥5,000 Mohm at 50 VDC

Safe / destructive load

150% / 300% F.S.

Excitation

4-12 VDC recommended, 15 VDC maximum

Construction

Alloy steel

Protection

IP67

Cable

52.5 ft (16 m)

Cable thread

1/4-18NPT (10-50 klb); 1/2-14NPT (50-125 klb)

Body length

7.8 in (10-25 klb) to 15.2 in (100-125 klb)

Features

NTEP 10,000 Divisions

Class IIIL approval under certificate 26-093 meets high resolution truck scale requirements.

300% Destructive Load

A wide overload margin takes the shock of a truck rolling onto the deck.

NPT Conduit Entry

1/4-18NPT and 1/2-14NPT threads accept standard US conduit fittings.

10-125 klb

Nine capacities cover light decks through heavy highway scales.

Applications

Truck Scales Weighing Bridges Weighing Modules Railroad Scales Silo Weighing Concrete Plants Waste Facilities Mining Operations

Downloads & Documentation

PDF
Load cell LP715x-20-093-NETP4.5 MB
Download
PDF
LP7151.pdf296.7 KB
Download

Need LP7151 for your application?

Tell us your capacity, accuracy class, and environment — our engineers will confirm fit and check live inventory.

COPYRIGHT© LOCOSC (USA) PRECISION TECHNOLOGY INC. ALL RIGHTS RESERVED.